Space Grade Screening

Renaissance has been designing and building circulators and isolators to meet the rigorous demands of both commercial and defense satellite applications for decades. All of our products are designed and tested to our unique customer requirements. This has expanded to include may other passive elements such as power dividers, filters, mixers, and more.

Renaissance often utilizes a standardized screening process, summarized below. This can be adapted to your unique requirements as needed.

Acceptance Testing

TestSampling BasisCondition
Pre-Cap Inspection100%Renaissance and HXI Inspection Procedure
Stabilization Bake100%
MIL-STD-883, Method 1008, Condition A or B, +90C for 48 hours minimum, prior to package seal
External Visual and Mechanical Examination100%
Parts shall be examined at 10X magnification
Initial Electrical Measurements100%
Tested at +25C for all parameters
Thermal Shock100%
MIL-STD-202, Method 107, temperature limits shall be -50C to +90C, 10 cycles
Interim Electrical Measurements100%
Testing performed at three temperatures, -40C, +25C and +85C for all parameters
Mechanical Shock100%
MIL-STD-202, Method 213. Pulse shall be half-sine and the peak acceleration shall be 1500g. The duration of the pulse shall be 0.3ms. 3 shocks on each axis
Vibration: Random100%
MIL-STD-202, Method 214, Acceptance Parameters (see Random Vibration Table, shown below)
Final Electrical Measurements100%
Testing performed at three temperatures, -40C, +25C and +85C for all parameters


Vibration Table
36 gms overall10 to 50 Hz: +3dG/octave50 to 100Hz: 0.8 g^2/Hz1000 to 2000 Hz: -3dB/octaveDuration 60 second/axis

Qualification Testing

TestMIL-STD-202 (unless otherwise specified) Condition
Initial ElectricalTested at +25C for all parameters
Thermal ShockMethod 107, temperature limits shall be -50C to +90C, 25 cycles
Vibration: RandomMIL-STD-202, Method 214, Qualification Parameters See Random Vibration Table below.
Final ElectricalTesting performed at three temperatures, -40C, +25C and +85C for all parameters

Random Vibration Levels

All Axes (X, Y, Z Axes)
Frequency (Hz)Acceleration PSD or Slope Level
Acceptance ParametersQualification Parameters
200.013 g2/Hz0.026 g2/Hz
20-50+ 6.0 dB/octave+ 6.0 dB/octave
50-8000.08 g2/Hz0.16 g2/Hz
800-2000-6.0 dB/octave-6.0 dB/octave
20000.013g2/Hz0.026g2/Hz
Overall10.0 grams14.1 grams
Duration60 seconds/axis120 seconds/axis